Extech 42509: The Ultimate Guide – Full Specifications, Comparisons, Manuals, Troubleshooting, And Where To Buy
Table of Contents
Extech 42509 Information
the information you requested about the Extech 42509 Dual Laser IR Thermometer with Color Alert.
Introduction
The Extech 42509 is a dual laser infrared thermometer with color alert. It has a maximum temperature measurement of 950°F (510°C) and a minimum temperature measurement of -4°F (-20°C). The meter has two laser pointers that help to quickly and accurately target the desired area. It also has a programmable high/low alarm that can be set to sound when the temperature reaches a predetermined level. The Extech 42509 is a versatile tool that can be used for a variety of applications, including electrical, mechanical, and HVAC troubleshooting.
Specifications
- Temperature range: -4°F to 950°F (-20°C to 510°C)
- Accuracy: ±1.5°F (±2°C)
- Resolution: 0.1°F (0.1°C)
- Spot size: 12:1
- Laser type: Dual laser
- Display: Dual LCD display with automatic backlight
- Alarms: Programmable high/low alarm
- Battery: 9V
- Dimensions: 5.5 x 3.1 x 1.7 inches
- Weight: 8 ounces
Features
- Dual laser pointers for quick and accurate target acquisition
- Programmable high/low alarm
- Automatic backlight for easy viewing in low-light conditions
- Adjustable emissivity for increased measurement accuracy
- Large, easy-to-read LCD display
- Durable construction
What's in the box
- Extech 42509 Dual Laser IR Thermometer
- Carrying case
- 9V battery
- Instruction manual
Conclusion
The Extech 42509 is a powerful and versatile infrared thermometer that is ideal for a variety of applications. It is accurate, easy to use, and has a variety of features that make it a great choice for professionals and hobbyists alike.
Here are some additional things to keep in mind when using the Extech 42509:
- Make sure that the target surface is clean and free of debris.
- Hold the thermometer at a distance of 1 to 12 inches from the target surface.
- If the target surface is very hot, use the included carrying case to protect the thermometer.
- Do not use the thermometer in flammable or explosive atmospheres.
Extech 42509 Compare with Similar Item
a table comparing the Extech 42509 to some similar items:
Feature | Extech 42509 | FLIR TG165 | Testo 885-1 |
---|---|---|---|
Price | $199.99 | $249.99 | $299.99 |
Accuracy | +/-1.5°F or +/-1°C | +/-1°F or +/-1°C | +/-1°F or +/-1°C |
Range | -40°F to 752°F (-40°C to 399°C) | -40°F to 752°F (-40°C to 399°C) | -40°F to 752°F (-40°C to 399°C) |
Resolution | 0.1°F or 0.1°C | 0.1°F or 0.1°C | 0.1°F or 0.1°C |
Spot size | 1.5° | 1.5° | 1.5° |
Display | 2.4" color LCD | 2.4" color LCD | 2.4" color LCD |
Battery life | Up to 200 hours | Up to 200 hours | Up to 200 hours |
Warranty | 3 years | 1 year | 3 years |
As you can see, the Extech 42509 is a very affordable option that offers good accuracy, range, and resolution. It also has a long battery life and a 3-year warranty. The FLIR TG165 and Testo 885-1 are more expensive, but they offer higher accuracy and resolution. They also have features that the Extech 42509 does not, such as image capture and wireless connectivity.
Ultimately, the best choice for you will depend on your individual needs and budget. If you are looking for an affordable option with good accuracy and range, the Extech 42509 is a great choice. If you need higher accuracy and resolution, or if you want features such as image capture and wireless connectivity, you may want to consider the FLIR TG165 or Testo 885-1.
Extech 42509 Problems and Solutions
some common issues and problems with the Extech 42509 multimeter and their solutions:
- The multimeter doesn't turn on. This could be due to a dead battery, a blown fuse, or a faulty power switch. To troubleshoot this issue, first check the battery to make sure it is inserted correctly and has a good charge. If the battery is fine, then check the fuse. If the fuse is blown, then it will need to be replaced. Finally, check the power switch to make sure it is turned on.
- The multimeter gives inaccurate readings. This could be due to a loose connection, a faulty sensor, or a problem with the internal circuitry. To troubleshoot this issue, first check all of the connections to make sure they are tight. If the connections are tight, then check the sensor to make sure it is working properly. If the sensor is working properly, then the problem may be with the internal circuitry. In this case, the multimeter will need to be repaired or replaced.
- The multimeter displays an error message. The error message will provide more information about the specific problem. To troubleshoot this issue, consult the multimeter's manual for the error code and its corresponding solution.
Here are some additional tips for troubleshooting common Extech 42509 multimeter problems:
- Always use the correct probes for the measurement you are taking. Using the wrong probes can damage the multimeter or give inaccurate readings.
- Do not exceed the maximum voltage or current rating for the multimeter. Doing so can damage the multimeter.
- Be careful when working with live circuits. Always use a voltage tester to make sure the circuit is dead before you begin working on it.
- If you are not comfortable troubleshooting multimeter problems, then take it to a qualified technician. Attempting to repair the multimeter yourself could damage it further.
I hope this helps!
Post a Comment for "Extech 42509: The Ultimate Guide – Full Specifications, Comparisons, Manuals, Troubleshooting, And Where To Buy"