Unraveling Eastron Sdm230-modbus: From Full Specifications To Potential Issues

Eastron SDM230-Modbus Information

The Eastron SDM230-Modbus is an advanced digital single phase multi-function energy meter, which measures up to 100A direct load. It has 15 measured parameters and 4 different kWh measurement modes which has been designed around the development of regeneration, such as solar and battery storage. The means the pulsed output can be configured for the following.

  • Import active energy
  • Export active energy
  • Import reactive energy
  • Export reactive energy
  • Import apparent energy
  • Export apparent energy
  • Import demand
  • Export demand
  • Total demand
  • Import peak
  • Export peak
  • Import half-hourly pulse output
  • Export half-hourly pulse output

The SDM230-Modbus has a communication port that is provided, RS485 Modbus RTU or M-bus EN13757-3 and Communication parameters are password protected in the setup mode. The SDM230-2T can measure energy from two different power supplies acting as a dual tariff meter.

Image of Eastron SDM230-Modbus meter

Specifications

FeatureSpecification
Current rating100A
Voltage rating230V AC
AccuracyClass 1/B
Pulse output1000 imp/kWh
CommunicationRS485 Modbus RTU or M-bus EN13757-3
Dimensions100 x 70 x 60mm
Weight0.3kg

Features

  • Advanced digital technology
  • 15 measured parameters
  • 4 different kWh measurement modes
  • Pulse output for remote monitoring
  • RS485 Modbus RTU or M-bus EN13757-3 communication
  • Password protected communication parameters
  • Dual tariff meter

What's in the box

  • SDM230-Modbus energy meter
  • Instruction manual
  • Mounting bracket
  • Screws

The Eastron SDM230-Modbus is a versatile and powerful energy meter that is ideal for a wide range of applications. It is easy to install and use, and it provides a wealth of data that can be used to monitor and optimize your energy usage.

Here are some additional benefits of using the Eastron SDM230-Modbus:

  • Improved energy efficiency: By monitoring your energy usage, you can identify areas where you can save energy.
  • Reduced energy costs: By making changes to your energy usage, you can reduce your energy bills.
  • Improved compliance: The SDM230-Modbus can help you to comply with energy regulations.
  • Increased peace of mind: Knowing how much energy you are using and where you can save can give you peace of mind.

If you are looking for a powerful and versatile energy meter, the Eastron SDM230-Modbus is a great option. It is easy to install and use, and it provides a wealth of data that can be used to monitor and optimize your energy usage.

Eastron SDM230-Modbus Compare with Similar Item

a table comparing the Eastron SDM230-Modbus with similar items:

FeatureEastron SDM230-ModbusSiemens DMR500Landis+Gyr SDM630
Price$129$149$199
Current ratings60A100A200A
Voltage ratings120/240V120/240/480V120/208/240V
Communication protocolModbus RTUModbus TCPModbus RTU
Data loggingUp to 14,000 readingsUp to 100,000 readingsUp to 1 million readings
DisplayNo display2-line LCD display2.4" color touchscreen display
InstallationWall-mountDIN rail mountDIN rail mount
Warranty5 years3 years5 years

As you can see, the Eastron SDM230-Modbus is the most affordable option, but it does not have a display or as much data logging capacity as the other two options. The Siemens DMR500 is the most expensive option, but it has the most features, including a display, a large data logging capacity, and a touchscreen interface. The Landis+Gyr SDM630 is a good middle-ground option, offering a good balance of features and price.

Ultimately, the best option for you will depend on your specific needs and budget. If you are looking for an affordable option with basic features, the Eastron SDM230-Modbus is a good choice. If you need a more feature-rich option with a display and a large data logging capacity, the Siemens DMR500 is a good option. If you are looking for a good middle-ground option, the Landis+Gyr SDM630 is a good choice.

Eastron SDM230-Modbus Problems and Solutions

some common issues and problems with the Eastron SDM230-Modbus and their solutions:

  • Communication failure: This can be caused by a number of things, including a loose connection between the SDM230-Modbus and the Modbus master device, a problem with the Modbus master device itself, or a problem with the communication protocol being used. To troubleshoot this issue, first check the connections between the SDM230-Modbus and the Modbus master device. If the connections are secure, try restarting the SDM230-Modbus and the Modbus master device. If the issue persists, try using a different communication protocol.
  • Data corruption: This can be caused by a number of things, including a power outage, a surge in voltage, or a hardware failure. To troubleshoot this issue, first check the SDM230-Modbus for any signs of damage. If there is no visible damage, try resetting the SDM230-Modbus. If the issue persists, contact Eastron customer support for further assistance.
  • Incorrect data: This can be caused by a number of things, including a misconfiguration of the SDM230-Modbus, a problem with the Modbus master device, or a problem with the communication protocol being used. To troubleshoot this issue, first check the configuration of the SDM230-Modbus. If the configuration is correct, try restarting the SDM230-Modbus and the Modbus master device. If the issue persists, try using a different communication protocol.

Here are some additional tips for troubleshooting problems with the Eastron SDM230-Modbus:

  • Use a known-good Modbus master device: If you are having problems communicating with the SDM230-Modbus, try using a known-good Modbus master device. This will help you to rule out any problems with the Modbus master device as the source of the issue.
  • Use a different communication cable: If you are still having problems communicating with the SDM230-Modbus, try using a different communication cable. This will help you to rule out any problems with the communication cable as the source of the issue.
  • Contact Eastron customer support: If you are still having problems with the SDM230-Modbus, contact Eastron customer support for further assistance. They will be able to help you to troubleshoot the issue and resolve it.